Research Article | Open Access

Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia

    Ararso Dereje Janbo ORCID

    Irba Muda Secondary School, Irba Muda Town, Anna Sora District, Guji Zone, Oromia Regional State, Ethiopia

    Melaklu Zigde Haile LiveDNA ORCID

    Department of Chemistry, College of Natural and Computational Science, Hawassa University, Hawassa, Ethiopia


Received
31 Aug, 2026
Accepted
10 Nov, 2026
Published
31 Dec, 2026

Background and Objective: Drinking water should be free unwanted constituent, contaminant, or impurity and fulfill quality requirements (desirable and permissible limits) recommended national and international organizations. This study evaluated the quality of drinking groundwater in selected Kebeles of Ana Sora District, Guji Zone, Oromia Regional State, Ethiopia, by analyzing physicochemical parameters, minerals, trace elements, and heavy metals. Materials and Methods: Groundwater samples were collected from selected Kebeles of Ana Sora District, Ethiopia. Temperature, pH, electrical conductivity (EC), and total dissolved solids (TDS) were measured using an AD8000 pH/mV/EC/TDS/Temp meter. Total hardness (TH), total alkalinity (TA), and chloride were determined using titration methods. Calcium (Ca), Magnesium (Mg), Copper (Cu), Manganese (Mn), Nickel (Ni), Cobalt (Co), Chromium (Cr), and Lead (Pb) concentrations were analyzed using Flame Atomic Absorption Spectrometry (FAAS). The obtained results were compared with the acceptable limits specified in the Compulsory Ethiopian Drinking Water Specifications. One-way Analysis of Variance (ANOVA) for the heavy metal dataset was performed to determine significant differences among the groundwater samples, with statistical significance set at p<0.05. Results: The average values of the physicochemical parameters investigated in this study were found to be in the range: Temperature (20.8-23.1) °C, pH (6.6-7.1), EC (23.7-48.0) μS/cm, TDS (8.5-24.5) mg/L, TH (14.7-42.4) mg/L, TA (23.3-38.3) mg/L and chloride (2.3-3.8) mg/L. The mean concentrations of the minerals were found to be in the range: Ca (2.32-9.62) mg/L, Mg (11.9-19.7) mg/L, and Cu (0.13-0.30) mg/L. Metals such as Mn, Ni, Co, Cr, and Pb were found to be below the detection limit of the instrument. One-way-ANOVA analysis showed that there were significant variations (p<0.05) in the quantified metal among the drinking groundwater samples. Conclusion: Groundwater quality in the Ana Sora District complied with the Compulsory Ethiopian Drinking Water Specifications (CES 58:2019) for all investigated physicochemical parameters and heavy metals. The soft water, near-neutral pH, low salinity, and non-detectable toxic trace metals (

Copyright © 2026 Janbo and Haile. This is an open-access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. 

INTRODUCTION

According to WHO/UNICEF1, improved drinking water sources are defined by the nature of their design and construction, have the potential to deliver safe water, and include piped water, boreholes or tube wells, protected dug wells, protected springs, rainwater, and packaged or delivered water. Drinking water sources such as ponds, lakes, rivers, and open-dug wells are considered unimproved. In addition, drinking water sources that are poorly constructed or do not have any engineered facilities such as spring boxes, borehole capping, and wells are also considered as unimproved2. The use of unimproved water sources usually associated with the presence of indicator bacteria and elevated levels of harmful substances or pollutants1,3,4 could cause water contamination and lead to several diseases such as cholera, dysentery, salmonellosis, and typhoid5,6. Waterborne diseases associated with these are attributed to the death of millions in developing countries every year7. According to World Health Organization (WHO), more than 16% of populations across the world have a shortage of safe drinking water sources8. As a result, death recorded to poor quality of drinking water is very high in developing countries (99.8%)9, and about 1.7 million losses and 54.2 million disability-adjusted life-years worldwide are attributable to unsafe water and poor sanitation and hygiene problem10. Additionally, the study indicated that about one-fourth of the world's population used unsafe water in 2010 and more than one-six worlds’ population use water from water sources with substantial hygienic hazards11.

Ethiopia has a significant challenge to increase the water quality coverage to achieve the sustainable development goals (SDGs) aim at universal access to safe water supply and sanitation12. Safe water supply includes the quality of water at the sources or drinking water must be free from pathogens and elevated levels of harmful substances at all times. So, the quality of drinking water can be compromised when it is contaminated by waste from various sources. The sources of water contamination could be geological, industrial, and agricultural activities. These contaminants are further categorized as microorganisms, inorganics, organics, and radionuclides. They can affect the quality of water and then human health upon consumption before proper treatment13. Particularly in Guji Zone Anasora wereda the community uses groundwater point sources located in different parts of the town as one of their major sources of drinking water without any form of treatment. Moreover, these water sources could be affected by the uses of more agricultural inputs such as fertilizers as the area is mild productive. Therefore, this study focused on the assessment of the levels of selected elements and physicochemical parameters in drinking groundwater samples collected from various groundwater sources in Anasora Woreda, Guji Zone, Oromia Regional State, Ethiopia.

MATERIALS AND METHODS

Description of the study area: The study was conducted in Oromia Regional State of Ethiopia, Guji Zone, Ana Sora District (Fig. 1). Guji Zone is one of the 18 Zones of Oromia Regional State. It is found in Southern part of the Oromia Regional State. The capital town of the Zone is Nagelle, which is 604 km far away from Addis Ababa, the capital city of Ethiopia. Guji Zone is bounded by Southern Nation, Nationality and Peoples Regional State in North, Somali Regional States in South, Borena Zone in West and Bale Zone in East. Guji Zone is located between 38°-40° East longitude and latitude 4°-5° on the North, and the altitude ranges from 500 m up to 3500 m above sea level. The area of the Zone is estimated to cover about 18,557.05 km2 or 3,545,400 hectare. Of which, around 1,392,048.05 hectare is arable land, while 702,080 and 1,167,145 hectare of its land is grazing and forest land, respectively14. The Zone accommodates three types of climate conditions- Dega, Woina Dega and Kolla and accounts 13, 19 and 68%, respectively. The zone has bi-modal rain seasons namely the summer (June to November) and spring (March to May). In the Dega areas, the rain ranges from 1000-1500 mm, Woina Degas 750-1000 mm and Kola areas 500-750 mm get annually14. Currently, Guji Zone has thirteen districts and two urban administrations. This study was confined to the newly established districts in (2006), known by the name Ana Sora as the society appeared to use groundwater sources extensively for various purposes.

Fig. 1: Location map of the study area

Sample collection, field physicochemical measurements, preservation, and preparation
Sample collection: Groundwater samples were collected and analyzed over a three-month period between June 2026 and August 2026 across three kebeles within the Ana Sora District: Bube Korsa, Hiyo Komole, and Irba Buliyo. To evaluate general water chemistry parameters (temperature, pH, electrical conductivity, total dissolved solids, total alkalinity, total hardness, and chloride), one representative groundwater sample was collected per kebele, yielding three samples in total. Conversely, for heavy metal characterization, a comprehensive spatial and temporal sampling strategy was used to yield three distinct composite samples per kebele, resulting in a total of nine composite groundwater samples for heavy metal analysis. To achieve this, three groundwater points were randomly selected from both Bube Korsa and Hiyo Komole. Because Irba Buliyo kebele contains only a single groundwater point, three separate composite samples were collected from this single source over the three-month period, spanning from June to August.

Field physicochemical measurements, and preservation: For the general water chemistry parameters including temperature, pH, and electrical conductivity (EC), and total dissolved solids (TDS) triplicate measurements were taken immediately on-site from the single representative sample per kebele using a portable AD8000 pH/mV/EC/TDS/Temperature meter. The laboratory determination of total alkalinity, total hardness, and chloride content was also carried out from these identical single-representative samples. For the heavy metal sample set, equal volumes of the collected sub-samples at each designated point were thoroughly homogenized in a clean, sterilized container to form the final representative composite samples. Immediately following mixing, these metal analysis samples were acidified by adding 2.0 mL of concentrated nitric acid (HNO3), 69-72%) to prevent metal precipitation and wall adsorption. All sample bottles were stored in an ice-filled cooler box at approximately 4°C during transit and maintained in a laboratory refrigerator at 4°C until chemical analysis15.

Sample preparation: Digestion of water samples: A standard nitric acid digestion technique was employed to prepare the samples for total metal determination, effectively reducing organic matrix interference and converting particulate-bound metals into a detectable free-ionic form15. For each sample, a 100 mL aliquot of the well-mixed, acid-preserved groundwater was transferred into a digestion flask. Inside a laboratory fume hood, 2 mL of concentrated (HNO3, 69-72%) was added, and the flask was covered with a ribbed watch glass to prevent contamination. The mixture was then subjected to a slow boil and evaporated on a hot plate (Spectrum Hot Plate) to a minimum volume of approximately 10 to 20 mL, ensuring the sample did not dry out completely. After cooling, the inner walls of the flask and the watch glass cover were rinsed down into the flask using distilled water. The solution was filtered into a 100 mL volumetric flask, diluted to the mark with distilled water, and thoroughly mixed to prepare it for total metal determination via Atomic Absorption Spectrometry (AAS). All groundwater samples were processed using this identical procedure. Additionally, a reagent blank was prepared using the same acid volume and underwent the exact same digestion sequence to correct for any potential trace impurities introduced by the reagents or water.

Apparatus and instrument: Various laboratory apparatuses and analytical instruments were utilized to determine the heavy metal concentrations and physicochemical parameters of the groundwater samples. Digestion was carried out using 250 mL round-bottom flasks, while borosilicate volumetric flasks (50 and 100 mL) were employed for sample dilution and standard solution preparation. Precise volumetric measurements of samples, acid reagents, and metal standards were performed using DURAN measuring cylinders, PYREX pipettes, and DRAGON LAB micropipettes (20-50 and 100-1000 μL). Following digestion, samples were filtered using Whatman No. 42 filter papers. On-site physicochemical parameters including temperature, pH, electrical conductivity (EC), and total dissolved solids (TDS) were recorded using an AD800 pH/mV/EC/TDS meter (Adwa Instruments, Hungary). Total metal concentrations were determined using a Flame Atomic Absorption Spectrophotometer (Buck Scientific, Model 210VGP AAS, USA) equipped with a deuterium background corrector, hollow cathode lamps, and an air-acetylene flame atomizer.

Chemicals and reagents: All chemicals and reagents utilized throughout this study were of analytical grade. Concentrated nitric acid (HNO3, 69-72%, Riedel-de Haen) was employed for sample digestion and preservation. For heavy metal analysis, commercially prepared 1000 mg/L stock standard solutions of Calcium (Ca), Magnesium (Mg), Copper (Cu), Manganese (Mn), Cobalt (Co), Chromium (Cr), Nickel (Ni), and Lead (Pb) (Buck Scientific, Puro-Graphic) were used to prepare intermediate and working standard solutions. For general water chemistry determinations, hydrochloric acid (HCl, 37%) and phenolphthalein were utilized to measure total alkalinity. Silver Nitrate (AgNO3), Sodium Chloride (NaCl), and Potassium Chromate (K2CrO4) were used for chloride content determination via Argentometric titration. To determine total water hardness, Ethylenediaminetetraacetic Acid (EDTA), Eriochrome Black T (EBT), Magnesium Sulfate (MgSO4), and an ammonium chloride/ammonia (NH4Cl/NH3) buffer solution were employed. High-purity distilled water was used exclusively for all sample dilutions, standard preparation, and the thorough rinsing of glassware and sample bottles.

Field physicochemical measurements: An AD8000 multi-parameter meter was utilized to measure groundwater temperature, pH, electrical conductivity (EC), and total dissolved solids (TDS) immediately at the point of collection.

Determination of total alkalinity: Alkalinity is a useful measure of the capacity of water to resist acidification from acid precipitation. The presence of carbonate, bicarbonate, and hydroxide ions impart the alkalinity of natural or treated waters. Total alkalinity was determined by acid-base titration using methyl orange as the endpoint indicator16,17. For each analysis, a 100 mL aliquot of the groundwater sample was pipetted into a 250 mL conical flask, followed by the addition of three drops of methyl orange

indicator. The solution was then titrated against a standardized 0.10 N Hydrochloric Acid (HCl) solution until the indicator color shifted sharply from yellow to red. This titration volume (V2), in mL corresponds directly to the cumulative sum of carbonates and bicarbonates present in the aqueous solution. To ensure analytical precision, all titrations were performed in triplicate, and the mean titrant volume was used to calculate total alkalinity as:

(1)

Determination of total hardness (TH): Hard waters are the waters that require a considerable amount of soap to produce foam and also produce scale in hot water pipes, heaters, boilers, and kettles. The hardness index is used to measure the concentration of Ca2+ and Mg2+ ions in water. Chemically, the hardness index is defined as the sum of the concentration of Ca2+ and Mg2+. Hardness is traditionally expressed as the mass (in mg) per liter of water calcium carbonate that contains the same number of dispositive (2+) ions. In this study, hardness is measured by titration of a water sample against standard EDTA at pH 10 and using an indicator (EBT) solution to signal the endpoint. Consequently, the hardness of water can be calculated by measuring the amount of EDTA consumed by a water sample and relating this to the concentration of dissolved calcium and magnesium ions. Total hardness, representing the cumulative concentration of calcium and magnesium ions, was measured using the EDTA complexometric titration method. For each determination, a 100 mL aliquot of the groundwater sample was pipetted into a clean 250 mL Erlenmeyer flask. To maintain a stable alkaline environment for metal-complex formation, 10 mL of an ammonia/ammonium chloride buffer solution was added, followed by three drops of Eriochrome Black T (EBT) indicator, which imparted a characteristic wine-red color to the solution. This mixture was then titrated against a standardized 0.01 M EDTA solution until a sharp color transition from wine-red to a pure sky-blue endpoint was observed. Titrations were repeated to obtain concordant values, and the recorded titrant volume was used to calculate total hardness, expressed as milligrams of calcium carbonate per liter, as18:

Total hardness = Molar mass of  CaCO 3 × 1000 × M EDTA × V EDTA used in the titration Volume of water sample (mL) used
(2)

Determination of chloride: Chloride is one of the major inorganic ions in water and wastewater. In potable water, the saltiness is variable and dependent upon both the concentration of chloride ions and the presence of other ions (Na, K, Ca, and Mg,). There are many potential sources of chloride in natural and drinking waters. The chloride concentration is higher in wastewater than in raw water because sodium chloride is a common article of diet and passes unchanged through the digestive system. Along the sea, coast chloride may be present in high concentrations because of the leakage of salt water into the sewage system. In addition, high chloride contents may harm metallic pipes and structures as well as growing plants. One of the analytical procedures to determine the chloride concentration is Mohr’s titration19. Chloride concentrations were determined via the Argentometric titration method. A standard 0.0141 M Silver Nitrate (AgNO3) titrant solution was prepared by dissolving 2.4 g of powdered AgNO3 in distilled water and diluting to volume in a 1000 mL volumetric flask. This solution was then transferred into a well-rinsed 50 mL burette. For the analysis, a 50 mL aliquot of each groundwater sample was measured into a conical flask, followed by the addition of 1.0 mL of potassium chromate indicator solution. The mixture was titrated against the AgNO3 solution until the appearance of a persistent reddish-brown precipitate signaled the endpoint. All titrations were performed in triplicate to obtain an average titrant volume.

Table 1: Instrumental conditions for each element analyzed
Elements Ca Mg Cu Mn Co Cr Ni Pb
Wavelength (nm) 422.7 285.2 324.7 279.5 240.7 357.9 239.7 283.2
Slit width (nm) 0.7 0.7 0.7 0.7 0.2 0.7 0.2 0.7

Table 2: Concentrations of working standards for each metal analysed using FAAS
Ca Mg Cu Mn
0.5; 1.0; 2.0; 4.0 0.05; 2.0; 4.0; 6.0 0.008; 0.5; 1.5; 2.0 0.05; 0.1; 0.5; 1.0
Ni Co Cr Pb
0.06; 0.1; 0.5; 1.0 0.06; 0.5; 1.0; 2.0 0.05; 0.5; 1.0; 2.0 0.09; 0.1, 0.5; 1.0

Additionally, a blank value was established by titrating a 50 mL aliquot of distilled water under the identical procedure to correct for any baseline interferences. The net titrant volume was subsequently used to calculate the final concentration of chloride ions using the following Eq. 319:

(3)

Where:

  A = Volume of titrant used for the water sample
  B = Volume of the titrant used for the blank (distilled water)

Determination of Ca, Mg, Cu, Mn, Co, Cr, Ni, and Pb: The determination of total heavy metal concentrations (Ca, Mg, Cu, Mn, Co, Cr, Ni, and Pb) was carried out using a Flame Atomic Absorption Spectrometer (Model 210VGP AAS, Buck Scientific, Inc., USA). For each element, a multi-point calibration curve was established using four sequentially diluted working standard solutions prepared from certified 1000 mg/L stock standards. These working standards were aspirated into the flame atomizer, and their corresponding absorbance values were recorded. A linear regression calibration curve was then constructed by plotting the absorbance values as a function of analyte concentration. Only calibration curves demonstrating satisfactory linearity, defined by a correlation coefficient (r2) greater than or equal to 0.999, were accepted. Once linearity was verified, the digested sample solutions were aspirated, allowing the instrument to directly read the metal concentrations.

Instrument operating conditions and calibration for FAAS
Instrument operating condition of FAAS: The determination of target elements (Ca, Mg, Cu, Mn, Ni, Co, Cr, and Pb) was carried out after optimizing the instrumental parameters of the Flame Atomic Absorption Spectrophotometer (FAAS). For each analyte, the corresponding hollow cathode lamp was inserted into the turret, followed by precise alignment of the lamp position, slit width, and operating wavelength. The digested sample solutions were then successively aspirated into the air-acetylene flame atomizer. To ensure data reliability and analytical precision, three replicate determinations were performed for each sample, and the mean absorbance value was recorded. The specific instrument operating conditions optimized for each analyte are summarized in Table 1.

FAAS calibration: Instrument calibration for each target metal was performed by preparing a multi-point calibration curve consisting of four working standard solutions. These working standards were prepared via serial dilution of the certified 1,000 mg/L (ppm) elemental stock standard solutions. The specific concentrations utilized to construct the linear calibration curves for each analyte are presented in Table 2.

Method validation: Method validation was performed to verify that the analytical procedure was accurate, reliable, and fit for its intended purpose. Throughout the study, stringent quality assurance procedures and precautions were maintained to ensure data integrity. High-purity distilled water and analytical-grade reagents were used exclusively, and reagent blank determinations were routinely analyzed to correct for baseline instrument readings and eliminate potential matrix interferences. To validate the accuracy of the overall analytical procedure, a recovery study was conducted by spiking pre-analyzed groundwater samples with known concentrations of multi-element metal standard solutions.

Method detection limit (MDL): Reagent blank samples were prepared in parallel with the groundwater samples following the identical acid digestion procedure. To estimate the method detection limit (MDL) for each target metal, six independent analytical blanks were processed. Each blank solution was analyzed via FAAS under the same operating conditions as the samples, and triplicate absorbance readings were recorded. The standard deviation (SD) of these blank concentrations was subsequently calculated and utilized to determine the MDL using the following Eq. 420:

MDL = 3 × Standard deviation of the blank
(4)

Method validation (recovery experiment): Due to the unavailability of certified reference materials (CRMs), the accuracy of the analytical procedure was evaluated via a spike-recovery experiment. A representative groundwater sample was selected, and a 100 mL aliquot was spiked with 50 μL of a combined standard solution containing known amounts of Ca, Mg, and Cu. This spiked matrix was then digested in triplicate following the identical procedure utilized for the water samples. The resulting digests were analyzed via FAAS to determine their respective metal concentrations. The data obtained from both the "spiked" and "unspiked" samples were subsequently used to calculate the percent recovery (%R) according to the following Eq. 520:

Recovery (%) = Amount recovered Spiked amount × 100 = Spiked sample result - Unspiked sample result Known spike added concentration × 100 →
(5)

Statistical data analysis: Statistical analysis of the groundwater quality data was performed using IBM SPSS Statistics (Version 16.0). Descriptive statistics including the mean, standard deviation (SD), and percent relative standard deviation (%RSD) were calculated based on the triplicate analytical measurements recorded for each parameter. Because field physicochemical measurements, total alkalinity, total hardness, and chloride content were determined using a single representative sample per kebele, analysis of variance was not applicable to these baseline parameters. Conversely, a One-way Analysis of Variance (ANOVA) was executed exclusively for the heavy metal datasets to identify statistically significant variations across the studied kebeles. When a significant difference was detected by the ANOVA (p<0.05), Tukey’s Honestly Significant Difference (HSD) post hoc test was applied to determine exactly which specific pairs of kebeles differed significantly from one another. A 95% confidence level (α = 0.05) was maintained across all statistical calculations.

RESULTS AND DISCUSSION

Physicochemical characteristics of groundwater: The physicochemical composition profiles (mean, standard deviation, and range) of the analyzed drinking groundwater samples are presented in Table 3.

Temperature: Temperature refers to degree of hotness or coldness and it can be measured in degree Celsius. Drinking water temperature value of the three sampling locations such as Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 22.0-22.8, 22.9-23.5, and 20.0-21.5°C at the point of distribution to the consumer, respectively.

The drinking water temperature range for the three water samples were below the drinking water temperature reported in the city of Cali (Colombia) resulted in temperatures between 25 and 28°C21.

Table 3: Physicochemical composition of drinking groundwater collected from selected Kebeles of Ana Sora District, Guji Zone, Ethiopia
Temperature (°C) pH Electrical conductivity (μS/cm)
Sample location Mean±SD Range Mean±SD Range Mean±SD Range
Bube Korsa 22.5±0.4 22.0-22.8 6.6±0.1 6.49-6.75 37.0±0.1 36.4-37.6
Hiyo Komole 23.1±0.3 22.9-23.5 7.1±0.1 6.97-7.18 23.7±0.5 23.2-24.0
Irba Buliyo 20.8±0.8 20.0-21.5 6.9±0.1 6.70-6.98 48.0±0.1 47.0-48.7
Sample TDS (mg/L) Total hardness
(mg/L CaCO3)
Total alkalinity
(mg/L CaCO3)
Chloride (mg/L)
location Mean±SD Range Mean±SD Range Mean±SD Range Mean±SD Range
Bube Korsa 12.8±0.2 12.67-12.98 42.4±2.1 40.04-44.04 25.0±5.0 20.0-30.0 2.5±0.5 1.98-2.98
Hiyo Komole 24.5±0.4 24.05-24.85 14.7±1.5 13.01-16.01 38.3±7.6 30.0-45.0 3.8±0.7 2.98-4.47
Irba Buliyo 8.5±0.1 8.42-8.65 33.0±2.0 31.023-35.03 23.3±2.9 20.0-25.0 2.3±0.3 1.98-2.48

pH: pH is a term used universally to express the intensity of the acid or alkaline condition of a solution. The pH for drinking water generally lies between 6.5 and 8.5 at 25°C22. However, high pH causes a bitter taste, water pipes and water-using appliances become coated with deposits and it depresses the effectiveness of the disinfection of chlorine, thereby causing the need for additional chlorine when pH is high. Low pH water will corrode or dissolve metals and other substances23. In the present study, the pH value of drinking water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 6.49-6.75, 6.97-7.18, and 6.70-6.98, respectively. These pH values were within the acceptable pH range specified in Ethiopian Standards22.

Electrical conductivity: Electrical conductivity is a measure of the ability of water to conduct an electrical current and it depends on the total amount of dissolved salts present in a water sample. In the present study, the electrical conductivity value of drinking water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 36.4-37.6, 23.2-24.0, and 47.0-48.7 μS/cm, respectively. These values were below the maximum permissible limit of electrical conductivity in drinking water, prescribed as 1500 and 2000 μS/cm10,22. The water samples from the three sampling locations were categorized as excellent, because the measured electrical conductivity values for all water samples fall in the range 0-333 μS/cm24. Moreover, the observed electrical conductivity value in all the three type of drinking water samples were the lowest as compared to previous study by Meride and Ayenew25 (192.14 μS/cm), Kassegne and Leta26 (63.96 μS/cm to 300.37 μS/cm), and Lewoyehu27 (34-304 μS/cm).

TDS: TDS is the overall measure of the inorganic salts (calcium, magnesium, potassium, sodium, bicarbonates, chlorides, and sulfates) dissolved in the groundwater. The total dissolved solids for water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 12.67-12.98, 24.05-24.85, and 8.42-8.65 mg/L respectively with maximum value recorded in Hiyo Komole and minimum value recorded in Irba Buliyo. According to the WHO standards and Ethiopian drinking water guidelines10,22, the highest desirable and highest permissible level for total dissolved solids is 500 and 1000 mg/L, respectively. Therefore, TDS values for all the studied drinking groundwater samples were below WHO standards and Ethiopian drinking water guidelines and they are classified as fresh and excellent (<300 mg/L) water28. Moreover, the observed total dissolved solids value in all the three type of drinking water samples were the lowest as compared to previous study by Kassegne and Leta26 (58.17 to 269.4 mg/L).

Total hardness: Hardness is simply the resistance of water in forming lather with soap. It is caused by dissolved metallic ions, predominantly calcium and magnesium cations. Hardness is most commonly expressed as milligrams per liter of calcium carbonate. The total hardness for water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 40.04-44.04, 13.01-16.01, and 31.03-35.03 mg/L CaCO3 respectively with maximum value recorded in Bube Korsa and minimum value recorded in Hiyo Komole. The values of total hardness for all of the drinking groundwater samples lied far below the maximum permissible limit specified in WHO standards and Ethiopian drinking water guidelines10,22. According to the classification of water based on total hardness value29, all the studied drinking groundwater samples were belonged to soft water. The observed total hardness value in Hiyo Komole and Irba Buliyo drinking water samples were below reported value of total hardness in previous study by Kassegne and Leta26 (40 to 215 mg/L CaCO3). However, hard water is not a serious health concern, but it may affect the acceptability of drinking water30.

Total alkalinity: The total alkalinity is typically defined as a measure of the capacity of water to neutralize a strong acid. It is a measure of the presence of bicarbonate, carbonate or hydroxide constituents. In this study, the total alkalinity for water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 20.0-30.0, 30.0-45.0, and 20.0-25.0 mg/L CaCO3 respectively with maximum value recorded in Hiyo Komole and minimum value recorded in Irba Buliyo. The values of total alkalinity for all of the drinking groundwater samples lied far below the maximum permissible limit specified in Ethiopian drinking water guidelines22. There is no health concerns related to alkalinity. However, water with low levels of alkalinity (less than 150 mg/L) is more likely to be corrosive. High alkalinity water (greater than 150 mg/L) may contribute to scaling.

Chloride: The concentration of chloride for water samples taken from Bube Korsa, Hiyo Komole, and Irba Buliyo were ranged from 1.98-2.98, 2.978-4.47, and 1.98-2.48 mg/L, respectively. These values were very much below the maximum limit specified in Ethiopian drinking water guidelines22. However, there is no health standard. Chloride levels less than 10 mg/L are desirable, while chloride levels more than 250 mg/L may cause a salty taste.

Analytical precision and field physicochemical measured parameter variability: Across all three sampling locations, the exceptionally low standard deviations (SD≤0.8 for temperature, SD = 0.1 for pH, and SD≤0.5 for EC) demonstrate excellent analytical precision and high instrumentation reproducibility during the on-site triplicate measurements. The narrow gaps between the minimum and maximum limits of the recorded ranges further underscore the stability of the water matrices at the time of testing. For instance, the tightest distribution for temperature was noted in Hiyo Komole (22.9-23.5°C), indicating highly uniform thermal conditions during collection, whereas Irba Buliyo exhibited a slightly broader thermal range (20.0-21.5°C), which accounts for its higher standard deviation of ±0.8°C.

For pH, all three kebeles displayed remarkable chemical stability with identical standard deviations of ±0.1, confirming the consistency of hydrogen ion concentrations within the local aquifer systems. A similarly high level of precision was observed in the electrical conductivity (EC) datasets. The ranges for Bube Korsa (36.4-37.6 μS/cm) and Irba Buliyo (47.0-48.7 μS/cm) demonstrated marginal variance, indicating minimal measurement fluctuation. Even at the lowest recorded conductivity levels in Hiyo Komole (23.7±0.5 μS/cm), the tight clustering of the range between 23.2 and 24.2 μS/cm verifies the robust reliability of the multi-parameter field probe and the absence of significant random error.

For Total Dissolved Solids (TDS), the data exhibited extreme stability with minor deviations, ranging from a low of 8.42-8.65 mg/L in Irba Buliyo (SD = ±0.1) to a maximum baseline of 24.05-24.85 mg/L in Hiyo Komole (SD = ±0.4). This minimal fluctuation confirms that the dissolved mineral content remained highly stable across individual sampling trials.

Evaluation of hardness, alkalinity, and chloride variability: The recorded standard deviations and narrow minimum-to-maximum ranges across the chemical datasets indicate high reproducibility and strong parameter consistency within each kebele. For total hardness datasets for Bube Korsa (42.4±2.1 mg/L CaCO3) and Irba Buliyo (33.0±2.0 mg/L CaCO3) displayed well-contained ranges, while Hiyo Komole showed the lowest overall hardness concentration (13.01-16.01 mg/L CaCO3), indicating consistently soft groundwater characteristics across the district.

Table 4: Calibration graph equation and R2 value
Metal Calibration equation R2 Value
Ca Y = 0.0503x+0.0019 0.9998
Mg Y = 0.0016x+0.0001 0.9995
Cu Y = 0.0518x+0.0013 0.9997
Mn Y = 0.1127x-0.0007 0.9996
Ni Y = 0.0269x+0.0005 0.9993
Co Y = 0.0435x-0.00031 0.999
Cr Y = 0.0751x+0.0005 0.9993
Pb Y = 0.0276x- 0.0003 0.9998

Table 5: Method detection limit for the target elements determined in drinking groundwater samples
Element Ca Mg Cu Mn Ni Co Cr Pb
IDL (mg/L) 0.05 0.005 0.005 0.03 0.05 0.05 0.04 0.08
MDL (mg/L) 0.5 0.05 0.008 0.05 0.06 0.06 0.05 0.09

Total alkalinity values exhibited a slightly broader distribution. Hiyo Komole displayed the widest alkalinity range (30.0-45.0 mg/L CaCO3), which mathematically accounts for its higher standard deviation of ±7.6 mg/L, while Bube Korsa and Irba Buliyo maintained narrower spreads with lower variances (SD = ±5.0 and ±2.9 mg/L, respectively). This minor variation is typical for alkalinity titrations in groundwater due to localized differences in carbonate equilibria. Finally, the chloride concentrations across all three kebeles demonstrated exceptional analytical precision, with uniform, low-level standard deviations (SD≤0.7 mg/L). The tightest chloride distribution was observed in Irba Buliyo (1.98-2.48 mg/L), verifying negligible baseline measurement error and a highly consistent low-salinity profile across the studied aquifer points.

FAAS calibration curve and linearity assessment: The calibration curves constructed for all target metals analyzed via FAAS demonstrated excellent linearity, with correlation coefficients (r2) consistently greater than or equal to 0.999. These high coefficients verify a robust, direct linear relationship between analyte concentration and instrumental absorbance across the calibrated ranges, ensuring the reliability of the subsequent quantitative determinations. The specific linear regression equations and their corresponding r2 values obtained for each metal are summarized in Table 4.

Method detection limits and instrumentation sensitivity: The calculated Method Detection Limit (MDL) values for each target element analyzed in the drinking groundwater samples are presented in Table 5. To establish analytical rigor, a clear distinction was maintained between the Instrument Detection Limit (IDL) and the MDL. The IDL reflects the absolute lowest analyte concentration the FAAS optics can distinguish from background noise using matrix-free, clean reference standards. Conversely, the MDL accounts for the entire sample preparation process including potential matrix interferences, acid digestion steps, and filtration defining the minimum concentration that can be detected and reported with 99% confidence. Crucially, all calculated MDL values were above the manufacturer-specified IDLs. This relationship confirms that the overall analytical method possessed sufficient sensitivity to reliably capture and quantify the baseline concentrations of the metals within the groundwater matrix.

Results of the concentration of Ca, Mg, Cu, Mn, Co, Cr, Ni, and Pb: The descriptive statistics including mean, standard deviation, and range of the elements analyzed in the drinking groundwater samples collected from the selected kebeles of the Ana Sora District, Guji Zone, are presented in Table 6. Among the target elements, Calcium (Ca), Magnesium (Mg), and Copper (Cu) were detected and quantified in allanalyzed groundwater samples, reflecting their continuous presence in the local aquifer systems. Conversely, the concentrations of Manganese (Mn), Nickel (Ni), Cobalt (Co), Chromium (Cr), and Lead (Pb) were found to be below the method detection limit (

Table 6: Concentration of quantified elements (mean+SD, n = 9, mg/L) in drinking groundwater samples from Ana Sora District
Ca Mg Cu
Sample location Mean±SD Range Mean±SD Range Mean±SD Range
Bube Korsa 2.32±0.16 1.80-2.60 19.7±1.1 11.5-25.0 0.19±0.01 0.07-0.34
Hiyo Komole 9.62±0.52 5.80-16.7 11.9±0.06 11.2-12.7 0.30±0.14 0.15-0.49
Irba Buliyo 4.6±0.04 4.10-5.30 24.6±0.02 24.3-24.9 0.13±0.01 0.12-0.14

Calcium: The calcium concentration in drinking groundwater samples collected from Bube Korsa, Hiyo Komole, and Irba Buliyo kebele were ranged from 1.80-2.60, 5.80-16.7, and 4.10-5.30 mg/L respectively (Table 6). Drinking groundwater samples from Hiyo Komole have the highest average calcium content with a value of 9.62±0.52 mg/L, while drinking water sample from Bube Korsa has the lowest calcium content with a value of 2.32±0.16 mg/L. However, the average calcium content in all investigated drinking groundwater samples were below the desired level recommended by Ethiopian Standards and WHO Standards22,31. Previous study had reported a calcium concentration of 2.19 to 46.11 mg/L for drinking water supplied to Ankober District, Amhara Region26, which is in agreement with the present study; Berihu Abadi Berhe32 reported calcium concentration in the wet season ranged from 41 to 178 mg/L in drinking groundwater Kombolcha Town Area, Eastern Amhara Region, which is higher than the present study.

The results of one-Way ANOVA analysis showed that there was a significant difference in the calcium content, F (2, 24) = 13.730, p<0.001, among the drinking groundwater samples obtained from the three kebeles. However, post hoc test revealed that the calcium content of drinking groundwater samples from Bube Korsa, and Irba Buliyo were statistically similar.

Magnesium: The magnesium concentration in drinking groundwater samples collected from Bube Korsa, Hiyo Komole, and Irba Buliyo kebele were ranged from 11.5-25.0, 11.2-12.7, and 24.3-24.9 mg/L respectively (Table 6). The average concentration of magnesium in the present study was ranged from 11.9 to 24. 6 mg/L with the highest average magnesium content were found in Irba Buliyo drinking water sample while the lowest average magnesium content was found in Hiyo Komole drinking water sample. Therefore, the average magnesium concentration in all investigated drinking groundwater samples were complied with the Ethiopian Standards and WHO Standards22,33. The average magnesium concentration obtained in this study were comparable with previous reported magnesium concentration, which is in the range of 4 to 25 mg/L32 for drinking water from Kombolcha Town Area, Eastern Amhara Region, Ethiopia.

One-Way ANOVA analysis showed that there was a significant difference in the magnesium content, F (2, 24) = 35.590, p<0.001, among the drinking groundwater samples obtained from the three kebeles.

Copper: The copper concentration in drinking groundwater samples collected from Bube Korsa, Hiyo Komole, and Irba Buliyo kebele were ranged from 0.07-0.34, 0.15-0.49, and 0.12-0.14 mg/L respectively (Table 6). The average concentration of copper in the present study was ranged from 0.13 to 0.30 mg/L with the highest average copper content were found in Hiyo Komole drinking water sample while the lowest average copper content was found in Irba Buliyo drinking water sample. Therefore, the average copper concentration in all investigated drinking groundwater samples were in compliance with the Ethiopian Standards and WHO Standards22,34. Moreover, the average concentrations obtained in this study were comparable with previous reported maximum copper concentration in the groundwater of the Middle Awash Basin, Ethiopia35.

Table 7: Percent recovery (%R) results for the quantified elements in Bube Korsa groundwater samples
Metal Conc. of unspiked sample (mg/L) Amount added
(50 μL of 1000 mg/L = 0.5 mg/L)
Conc. spiked sample (mg/L) Recovery (%R)
Ca 2.32±0.16 0.5 2.80±0.14 96
Mg 19.7±0.11 0.5 20.25±1.48 110
Cu 0.19±0.01 0.5 0.73±0.06 108
Recovery test results (mean±SD, n = 9, mg/L) for the analysed elements in Bube Korsa groundwater sample

The results of One-way ANOVA analysis showed that there was a significant difference in the copper content, F (2,24) = 6.549, p = 0.005, among the drinking groundwater samples obtained from the three kebeles. However, post hoc test revealed that the copper content of drinking groundwater samples from Irba Buliyo, and Bube Korsa were statistically similar.

Results of the recovery experiment: Recovery experiment was carried out using selected groundwater sample (Bube Korsa). The accuracy of the optimized analytical procedure was successfully validated through a matrix spike-recovery experiment, with results summarized in Table 7. Because the baseline concentrations of Ca, Mg, and Cu were well above the method detection limits, the recovery study was targeted specifically to these quantified elements to evaluate the accuracy of the final quantitative determinations. The calculated percent recovery (%R) values for Ca, Mg, and Cu all fell within the highly acceptable analytical range of 96.0% to 110%, demonstrating excellent method accuracy and negligible matrix suppression or enhancement.

Conversely, baseline concentrations for Mn, Ni, Co, Cr, and Pb were consistently below the MDL across all groundwater samples. While these elements were excluded from the sample matrix recovery calculations due to their non-detectable baselines, the strict control maintained via parallel reagent blanks and the linearity of their calibration curves (r2≥0.999) confirmed that the FAAS method retained robust analytical readiness for these trace analytes.

CONCLUSION

Physicochemical drinking water quality parameters such temperature, pH, Electrical conductivity, TDS, Total hardness, Total alkalinity, and chloride, and minerals such as (Ca, and Mg), trace elements (Cu, Mn, Ni, and Co) and heavy metals (Cr and Pb) were analysed to evaluate the quality of drinking groundwater samples collected from selected Kebeles of Ana Sora District, Guji Zone, Oromia Regional State, Ethiopia. The result showed that the values of all selected physicochemical parameters were within the acceptable standard specified in Compulsory Ethiopian Drinking Water Specifications (CES 58:2019). The consistently soft water characteristics, optimal near-neutral pH values, low salinity profiles, and completely non-detectable levels of toxic trace metals (

Metals such as Ca, Mg, and Cu were found and quantified in all drinking water samples while the concentration of Mn, Ni, Co, Cr, and Pb were found to be below the detection limit of the instrument. In general, the drinking groundwater supplied to the community in the studied kebeles were considered to be fit for human consumption although the number of sample considered in the study were not sufficient to conclude conclusively. Therefore, more research regarding the seasonal variation of the physicochemical parameters should be conducted in order to further strengthen the conclusion.

FUNDING

This research was funded by the Ministry of Education of Ethiopia.

ACKNOWLEDGMENT

We acknowledge the Ministry of Education of Ethiopia for funding the research and Hawassa University for allowing me to conduct the study.

REFERENCES

  1. Dangour, A.D., L. Watson, O. Cumming, S. Boisson and Y. Che et al., 2013. Interventions to improve water quality and supply, sanitation and hygiene practices, and their effects on the nutritional status of children. Cochrane Database Syst. Rev.
  2. Sitotaw, B., E. Melkie and D. Temesgen, 2021. Bacteriological and physicochemical quality of drinking water in Wegeda Town, Northwest Ethiopia. J. Environ. Public Health, 2021.
  3. Kumar, P., F. Arshad, S.K. Shaheen, A. Nadeem, Z. Islam and M.Y. Essar, 2022. Water sanitation in Karachi and its impact on health. Ann. Med. Surg., 77.
  4. Wolde, A.M., K. Jemal, G.M. Woldearegay and K.D. Tullu, 2020. Quality and safety of municipal drinking water in Addis Ababa City, Ethiopia. Environ. Health Prev. Med., 25.
  5. Duressa, G., F. Assefa and M. Jida, 2019. Assessment of bacteriological and physicochemical quality of drinking water from source to household tap connection in Nekemte, Oromia, Ethiopia. J. Environ. Public Health, 2019.
  6. WHO, 2019. Water, Sanitation, Hygiene and Health: A Primer for Health Professionals. World Health Organization, Geneva, Switzerland, Pages: 36.
  7. UNDP, 2006. Human Development Report 2006: Beyond Scarcity: Power, Poverty and the Global Water Crisis. United Nations Development Programme, New York, ISBN: 0230500587, Pages: 422.
  8. Sila, O.N., 2019. Physico-chemical and bacteriological quality of water sources in rural settings, a case study of Kenya, Africa. Sci. Afr., 2.
  9. Bulta, A.L. and G.A.W. Micheal, 2019. Evaluation of the efficiency of ceramic filters for water treatment in Kambata Tabaro Zone, Southern Ethiopia. Environ. Syst. Res., 8.
  10. WHO, 2004. Guidelines for Drinking-Water Quality: Volume 1. 3rd Edn., IWA Publishing, Geneva, Switzerland, ISBN: 9241546387, Pages: 515.
  11. Obeta, M.C. and C.F. Nwankwo, 2015. Factors responsible for rural residential water supply shortage in Southeastern Nigeria. J. Environ. Geogr., 8: 21-32.
  12. Dawes, J.H.P., 2022. SDG interlinkage networks: Analysis, robustness, sensitivities, and hierarchies. World Dev., 149.
  13. Rahmanian, N., S.H.B. Ali, M. Homayoonfard, N.J. Ali, M. Rehan, Y. Sadef and A.S. Nizami, 2015. Analysis of physiochemical parameters to evaluate the drinking water quality in the State of Perak, Malaysia. J. Chem., 2015.
  14. Demise, S. and A. Emire, 2024. Characterization and identification of major constraints and potentials of Kiltu Sorsa Watershed, in Guji Zone, Southern Ethiopia. J. Agric. Ecol. Res. Int., 25: 114-126.
  15. Zigde, H.M. and B.N. Begna, 2023. Physicochemical characteristics of drinking water sources and household tape water in Yabelo Town. Trends Appl. Sci. Res., 18: 131-148.
  16. Larson, T.E. and L. Henley, 1955. Determination of low alkalinity or acidity in water. Anal. Chem., 27: 851-852.
  17. Thomas, J.F.J. and J.J. Lynch, 1960. Determination of carbonate alkalinity in natural waters. J. Am. Water Works Assoc., 52: 259-268.
  18. Ojobo, K.C. and P. Adowei, 2021. Evaluation of physicochemical characteristics and carbonate equilibria system of the New Calabar River, Choba, Rivers State, Nigeria. J. Appl. Sci. Environ. Manage., 25: 1841-1847.
  19. Akaho, A.A., G.B. Tikeri and A.O. David, 2022. Physicochemical analysis of potable water in Baham Community, Western Region of Cameroon. J. Appl. Sci. Environ. Manage., 26: 1203-1209.
  20. Ripp, J., 1996. Analytical Detection Limit Guidance & Laboratory Guide for Determining Method Detection Limits. Wisconsin Department of Natural Resources, Laboratory Certification Program, Madison, Wisconsin, Pages: 24.
  21. Montoya-Pachongo, C., I. Douterelo, C. Noakes, M.A. Camargo-Valero, A. Sleigh, J.C. Escobar-Rivera and P. Torres-Lozada, 2018. Field assessment of bacterial communities and total trihalomethanes: Implications for drinking water networks. Sci. Total Environ., 616-617: 345-354.
  22. Gintamo, B., M.A. Khan, H. Gulilat, R.K. Shukla and Z. Mekonnen, 2022. Determination of the physicochemical quality of groundwater and its potential health risk for drinking in Oromia, Ethiopia. Environ. Health Insights, 16.
  23. Langelier, W.F., 1946. Effect of temperature on the pH of natural waters. J. AWWA, 38: 179-185.
  24. Sarr, A., S. Ndoye, A.L.T. Djanni and S. Faye, 2023. Assessment of groundwater quality for drinking and irrigation uses in the Samba Dia Area, Central West Senegal. J. Water Resour. Prot., 15: 130-148.
  25. Meride, Y. and B. Ayenew, 2016. Drinking water quality assessment and its effects on residents health in Wondo Genet Campus, Ethiopia. Environ. Syst. Res., 5.
  26. Kassegne, A.B. and S. Leta, 2020. Assessment of physicochemical and bacteriological water quality of drinking water in Ankober District, Amhara Region, Ethiopia. Cogent Environ. Sci., 6.
  27. Lewoyehu, M., 2021. Evaluation of drinking water quality in rural area of Amhara Region, Ethiopia: The case of Mecha District. J. Chem., 2021.
  28. Sharma, N., A. Thakur and J. Singh, 2025. Study of the groundwater quality and its suitability for drinking and irrigational use in Bathinda District, Punjab, India. Water Pract. Technol., 20: 2418-2434.
  29. Sawyer, C.N. and P.L. MacCarty, 1967. Chemistry of Sanitary Engineers. 2nd Edn., McGraw-Hill Publishing Co. Ltd., New York, United States, ISBN: 9780070549708, Pages: 518.
  30. WHO, 2011. Guidelines for Drinking-Water Quality. 4th Edn., World Health Organization, Geneva, Switzerland, ISBN: 9789241548151, Pages: 541.
  31. Saleh, H.M., S.B. Eskander, H.H. Mahmoud and M.I. Abdou, 2022. Groundwater quality and health assessments based on heavy metals and trace elements content in Dakhla Oasis, New Valley Governorate, Egypt. Water Sci., 36: 1-12.
  32. Berhe, B.A., 2020. Evaluation of groundwater and surface water quality suitability for drinking and agricultural purposes in Kombolcha town area, Eastern Amhara Region, Ethiopia. Appl. Water Sci., 10.
  33. Andrianou, X.D., C. van der Lek, P. Charisiadis, S. Ioannou and K.N. Fotopoulou et al., 2019. Application of the urban exposome framework using drinking water and quality of life indicators: A proof-of-concept study in Limassol, Cyprus. PeerJ, 7.
  34. Shajedul, M.S., 2022. Status of groundwater aquifers, water quality, sources of contamination, and future challenges in Bangladesh: A comprehensive review. J. Appl. Sci. Environ. Manage., 26: 1327-1342.
  35. Abebe, Y., T. Alemayehu, B. Birhanu, T. Alamirew and E. Alemayehu, 2024. Demystifying heavy metals and physicochemical characteristics of groundwater in a volcano-tectonic region of Middle Awash, Ethiopia, for multipurpose use. Sustainability, 16.

How to Cite this paper?


APA-7 Style
Janbo, A. D., & Haile, M. Z. (2026). Quality assessment of drinking groundwater in anasora woreda, ethiopia. Asian Journal of Biological Sciences, 19(4), 150–163. https://doi.org/10.3923/ajbs.2026.150.163

ACS Style
Janbo, A. D.; Haile, M. Z. Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia. Asian J. Biol. Sci 2026, 19 (4), 150–163. https://doi.org/10.3923/ajbs.2026.150.163

AMA Style
Janbo AD, Haile MZ. Quality assessment of drinking groundwater in anasora woreda, ethiopia. Asian Journal of Biological Sciences. 2026;19(4):150–163. doi:10.3923/ajbs.2026.150.163

Chicago/Turabian Style
Janbo, Ararso Dereje, and Melaklu Zigde Haile. 2026. “Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia.” Asian Journal of Biological Sciences 19 (4): 150–163. https://doi.org/10.3923/ajbs.2026.150.163